The first change of gearbox oil is after 100 hours of mixer operation.From the second time oil should be replaced every 1500 hours,Check regularly whether the oil deterioration,if found that the deterioration of oil,emulsification and other phenomena.Please timely replace oil,so as not to cause damage to the reducer
The standard mixer adopts well-known domestic brands,or international brands such as ABB and Siemens can be used according to customer requirements,and the price will be different
The standard mixer USES high chromium alloy liner and blade,and can also be customized according to different material requirements.
According to the calculation of mixing C30 ready-mixed concrete,the service life of the blade is 30,000 times and the life of the lining plate is 40,000 times
After using 200 squares, tighten the mixing arm and blade bolts in time, check the wear of the mixing arm blades every week to ensure the gap between the blades and the lining plate is 3-5mm. When the blades cannot be adjusted, replace the blades in time, and clean the mixing drums in time. Accumulate materials, back and forth to close the door, to ensure unloading unblocked.
1. Maintenance method: gear oil replacement.
2. Maintenance interval: the gear oil is replaced for the first time after running for 100h, and then replaced every interval of 1500h.
3. Refueling standard: Ensure that the gear oil can splash on the tooth surface.
4. Gear oil type and type: Great Wall L-CKD220 gear oil (Please refer to the host name plate for oil change standard).
1.Maintenance method: manual lubrication.
2 Maintenance interval: first lubrication after running for 100h, then refueling every 50h.
3. Lubricating oil type: NLGI 3# lithium grease 4. Check the planetary shaft for oil leakage every shift.
1. Maintenance method: replace cleaning.
2. Maintenance interval: Run the hydraulic oil for 100h, then change the hydraulic oil after running for 1500h-2000h, clean the solenoid valve reversing valve and the relief valve regularly every month to ensure the smooth inside of the valve body.
3. Hydraulic oil type: YB-N46 anti-wear hydraulic oil
Check the mixer liner, blade and powder discharge port for accumulation;
Check the mixer running time and the amount of each mixing, total production.
Check the sealing gap of the discharge door for each shift and adjust it; if it cannot be adjusted or leaked, replace it in time.